Design requirements for uninterruptible power supply for communications
1 This specification sets out the requirements for Transnet Pipelines (TPL) for the design and supply of an Uninterruptible Power Supply (UPS) system to be used for the powering of small, medium and large computerised control systems, variable speed drives, direct online motors, ICT equipment's such as servers and other relevant equipment's.
[PDF Version]
FAQS about Design requirements for uninterruptible power supply for communications
What is an uninterruptible power supply?
An uninterruptible power supply is a device that has the ability to convert and control direct current (DC) energy to alternating current (AC) energy . UPS is a battery backup for PC, when the power goes off the UPS kicks in and continues to supply power for some period of time to the particular system.
What are the requirements for an ups?
These requirements include the reliability of the prime power source, the nature of the work done, local and state regulations governing emergency power, etc. The process does not give a single solution that is applicable to all cases. Determine the general need for an UPS. Determine the purpose of the UPS. Determine the power requirements.
What is an uninterrupted power supply (UPS)?
The human desire to have a steady power supply for domestic and industrial purposes gave rise to an uninterrupted Power supply (UPS). Globally, the need and demand for computers, electronics, and other electrical devices are on the rise. These types of equipment required quality, high stability, and uninterrupted power supply.
What are the requirements for the ups to comply with IEC 62040-2?
The UPS shall conform to the electromagnetic emission and immunity levels in IEC 62040-2 for the specified category level. The sound pressure level, measured at a distance of one metre from the UPS in any direction, shall not exceed the specified value, at load conditions ranging from no load to the rated load.
Why should a ups be protected from a short-circuit?
The UPS should be so designed and constructed that it is protected against damage resulting from disconnecting the batteries or, with the battery disconnected, short-circuiting the UPS battery connections. If this protection is provided by electronic means it should automatically reset following removal of the open or short-circuit conditions.
What is the internal control supply of the ups?
The internal control supply of the UPS shall be available provided any of the power sources to the UPS are present. The inverter unit shall control the output of the UPS to maintain synchronism with the bypass voltage during variations in input frequency, within the specified tolerance limits.
-
Communication base station EMS line arrangement
* Department of Electronic Engineering, Tsinghua University, Beijing, P.R. China † School of Computer and Information Technology, Beijing Jiaotong University,. . In Section 3, we focused on the decision of base station intervals(i.e. how the train speed affects the interval). And from the above discussion, we see that the. . In this work, we discussed the issue of base station deployment using the concept of channel service. Specifically, we analyzed the relation between the base station.
[PDF Version]
FAQS about Communication base station EMS line arrangement
What are the two communication systems we take as a baseline?
The two communications systems we take as a baseline are the telephone system and the Internet. The two networks share physical links, but could scarcely be more different. The telephone system operates on the basis of fixed path connections set up as part of call initiation. It provides two-way voice communication of high quality.
How does a base station work?
Each base station is designed to operate with a number of frequencies at the same time, with pairs of separated frequencies used for transmit and receive. Operation of the air interface involves close interaction between the mobile and the base station. The following items are functions impact the base station system structure.
Can cellular base stations be standardized?
It is hoped that the model can also be the basis for standardization of base station components. The paper will focus on cellular base stations for two reasons. One is the importance of base stations in making possible the system capabilities that users want to use and that network operators want to offer.
How many base stations should be built?
The number of base stations to be located. This would depend on budget limitations. Optimal positioning of the base stations to maximize the coverage in the region given a restriction on the number of base stations to be built (particularly true in rural areas where the number of base stations is less and their locations are thus more critical).
What is the base station working group?
This document is a compilation of documents developed in the Base Station Working Group. It describes the structure of base station systems with a convergent top-down and bottom-up framework. The BSWG has now moved beyond detailed consideration of these specific contributions.
Why is a base station important?
In many cases the base station is most of the time only an intermediate component between the network and the handheld. However, in certain cases the downloading operation itself may have an influence on the way the base station has to work and so the base station is an important actor.